INTUMESCENT MEMBRANE PAPER/PANELLED DOOR UPGRADES

DESCRIPTION
Intumescent paper with thin white fireproof card face (1mm thick), for upgrading flat panelled doors to fire-rated doors. Also available with veneer or birch/Gaboon plywood. Intumescent paper can be supplied independently for use by door manufacturers. The product is applied with Envirograf® Product 46 (IA) adhesive. After fitting, the card and the plywood may be painted over or varnished. Intumescent membrane paper can be used between 4mm plywood panels if new doors are being made, giving 30 minutes of fire protection. Fit the paper between 12mm plywood panels for 60 minutes of fire protection.
USE
Applied to panels in doors, in conjunction with Product 42.
PERFORMANCE
Achieved in excess of 30 minutes of fire resistance on softwood doors made from 31mm stiles and rails, and panels 6mm or thicker. 60 minutes of fire protection can also be achieved. This intumescent paper has been fully tested to BS476 Part 22 (1987) on newly-manufactured and old doors, at UKAS-approved test centres. Also tested at VNE to European Standard EN1363-1 (2000).
ORDERING REFERENCES
ES/MP Paper only, for use in composite panel door manufactureES/MP/FC Paper with protective fire card for normal on-site upgrading
The intumescent paper is supplied adhered to fire card:
ES/MP/FC3 For painting over
ES/MP/GP gaboon ply facing
ES/MPV veneered finish (please ask for details of available finishes)
ES/MP/PLY (birch faced)
See price list for sizes and details.
For friendly advice, please ring us! 01932 268440